This is a 240V/30A auxiliary control panel designed for customers who already own Auber SSR based control panels, such as PCO series oven control panels. It provides additional support when upgrading to a larger oven or adding more heating elements to an existing oven, especially when the main control panel cannot manage the increased current or wattage. This 30A auxiliary panel connects directly to the main control panel for seamless operation.
DIY kit for this panel is also available. Please contact us.
Features:
- No separate temp control in this auxiliary panel. Your main PCO panel will control this panel.
- Enclosure with 1/2" Knockouts for easy connection.
- Mini 2-in-1 Volt and Amp meter for displaying system power level.
- Solid State Relay (SSR) for long lasting, fast and noise free power switching.
- Contactor for completely cut off power to the element.
- Strain-relief power cord connector for hard-wiring the power line.
- Assembled in U.S.
Important notes:
1. This auxiliary control panel doesn't have a PID controller nor a temperature sensor. It cannot be used by itself. It needs to be used together with the Auber PCO control panel for electric ovens including PCO104, PCO204, PCO304, PCO404 and PCO504 as well as Auber legacy PCO control panels. This panel is also compatible with other Auber SSR based control panels such as KLN102, MS100, STL102, STL201, SMK103 and more. For questions, please contact us.
2. This control panel needs to be powered up by a separate power supply. This control panel is designed for North America 240V AC power lines which require four line power connections (L1, L2, Neutral and Ground), same requirement as Auber PCO control panels. If you don't have neutral or if you are not in North America, please contact us.
3. This control panel comes with one output channel. There is one heater on/off switch on the front. Users can manually turn the connected elements OFF. If turning this switch to ON position, the connected elements are controlled by the main control panel.
3. By using this auxiliary panel together with your main control panel, you can increase the supported oven size by an additional 75 Cu.Ft.
4. Connection is required between the main PCO control panel and this auxiliary panel. Minimum modification is needed on the main PCO control panel. Please provide your control panel part number during the checkout.
Power input & output connection options:
By default, power input & output cords need to be hardwired into this control panel. If you need a power output socket instead, please
contact us.
Bottom View
Side View
Note:
1. The input power cord (SOOW 10/4) is not included because each user may have different hook up requirements.
2. Environment humidity is less than 85% RH.
3. This control system is designed for heating elements (resistive load) only, not for gas burners or propane heaters. Heating element is not included.
4. Sensor is not included.
5. Warranty: One (1) year limited warranty.
6. If you need a DIY kit for this control panel, please contact us.
7. Lead time for this product is 2-3 business days. Please contact us if you have any other questions.
This product was added to our catalog on Friday 16 August, 2024.